SPECIFICATION

Upto 3,000kWe at Alternator Output

Multistage 3 Fully Condensing


Description

DESIGN QUALITY & PERFORMANCE ASSURANCES AND ADVANTAGES

Trip and throttle (T&T) valve have advantage of: 
- Less valve stem jam problem.
- Lower steam pressure drops across the governor valve.

- Proven Steam Turbine Generator (STG) design manufactured, assembled & tested in Shinko Hiroshima, Japan.
- All Shinko STG are tested with Live Steam before delivery to customers to ensure quality units are delivered to site. Preventing the need for on-site rectification for new STG units. Shinko also provides opportunity to customers to witness the STG testing in Shinko Factory.
- Rotor is of solid shaft build-up design where rotor wheel is machined to size instead of the conventional shrink-fitted design.
- Shaft sealed using labyrinth packing which are easily maintained and reduce down-time instead of carbon rings that will cause long down-time of STG when doing maintenance (metal spray at worn shaft surface, etc.). Assisted by steam driven steam ejector to prevent condensate from mixing with lubrication oil in non-steam sections.
- Maintenance free Flexible Disc Coupling is implemented. No need to re-grease or oiled.
- Lubrication oil strainer is cleanable type without disposable filter element, thus more economical and environmentally friendly.


Additional Info

Dedication to operation & STG safety through wide range of alarms & trips:-

  1. Over-speed trip (electrical & mechanical)
  2. Low lubrication oil pressure alarm & trip
  3. High steam exhaust pressure trip
  4. Rotor vibration alarm & trip
  5. Axial displacement alarm & trip
  6. Manual Trip (on Turbine Control Panel)
  7. Remote Trip (in Central Control Room)
  8. Generator Trip
  9. Hand Trip
  10. High lubrication oil temperature alarm
  11. High reduction gear bearing temperature alarm
  12. Sentinel valve